This gas turbine is of the two shaft type, with a separate gas generator and a power turbine, developing a maximum electric power of 3.5kW. The fuel can be any fuel gas, propane, butane, natural gas, etc.
The power turbine is coupled through one belt to a synchronous motor that is first synchronised with the grid. The power produced can be injected into the grid or fed into a bank load.
The turbine is instrumented with a comprehensive monitoring, control and safety system and software.
The monitoring system covers the following variables:
- Power turbine developed electric power;
- Power turbine speed;
- Gas generator speed;
- Temperature of the gases at the combustion chamber outlet;
- Temperature of the gases at the power turbine inlet;
- Gases pressure at the outlet of the combustion chamber;
- Gas fuel flow rate;
- Air flow rate;
- Pressure loss at the air inlet filter;
- The model allows the complete study of an actual working turbine as well as the tracing of the Bryton diagram and thermal efficiency determination.
 |
| Gas Turbine Gas generator view |
| |
 |
| Gas Turbine combustion chamber |
| |
 |
| Power turbine |
| |